Over- Under Pressure Valve

We are able to deliver the right solution for PRv’s in every situation. For most environments, our two standard types of PRV’s will meet your needs. For other situations, we have many alternatives we can explore to meet your requirements.

Contact us

The biogas that is being produced inside your tank has a certain pressure, measured in mBar. In most situations, the pressure will be between -1,0 and +5,0 mBar. Our pressure valves verify that the gas pressure inside your tank does not exceed the maximum limit. Our PRv’s also have a very narrow flange connection (150 or 200 mm), which gives you the benefit of mounting the PRv’s higher on your tank, so you can fill the tank to a higher level.

Technical specifications and differences Over-/underpressure Valves:

PRV 450PRV 950
mBarMin -1 / Max +5Min -2 / Max +10
Max. gas flow450m³/h950m³/h
Flange ConnectionDN150DN200
Should be filled withWater / glycolWater / Glycol
Chimney1 meter1 meter
On request even higher

Over- Under Pressure Valve components